- Home
- Active Devices
- High Speed Copper Cables
- FDR QSFP+ 56Gb/s Copper Cable
Economic solution for within rack, or rack-to-rack applications
- General Details
- Product Specs
- Order Enquiry
- Documents
- Related Products
Characteristics
- Compatible with industry standard QSFP cages +Switches
- EEPROM signature can be customized
- FDR QSFP+cable assemblies are hot swappable
- The programmed EEPROM signature enables the host to differentiate between a copper cable assembly and a fiber optic module
- Low power consumption assists in making the passive copper cable assembly an economic solution for within rack, or rack-to-rack applications
Application
- InfiniBand 4X SDR, DDR, QDR, FDR
- Ethernet 10G,40G
- FiberChannel 10G,40G, SAN, 4x16G
- RapidIO, Myrinet 40G
- Rack-to-Rack, Shelf-to-Shelf Interconnect
- Networking, Storage
- Hubs, switches, routers, servers
Fiberon’s FDR QSFP+ passive copper cables provide robust connections for leading edge 56 Gb/s systems. They are designed to be fully compatible in form factor and optical/electrical connections according to the QSFP Multi- Source Agreement.
QSFP+ (Quad SFP+) connectors provide four channels of data in one pluggable interface. Each channel is capable of transferring data at 14.2Gbps and supports a total of aggregate 56Gbps as specified for QSFP+. These interconnects have three times the density of SFP+ interconnects (MSA) and have been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.
FDR Copper QSFP+assemblies are offered in different wire gauges (AWG) depending on length.
Wire Gauge | Cable Length |
---|---|
30AWG | ≤ 1Meter |
28AWG | ≤ 2Meters |
26AWG | ≤ 3Meters |
24AWG | ≤4Meters |
FDR QSFP+ 56Gb/s Copper Cable Overview
Test Type | Test Item | Target | Reference | |
---|---|---|---|---|
Electrical Characteristics |
Differential impedance | 100+/-10ohm (Rise time of 100ps (20%- 80%)) | InfiniBand Specification Volume 2 | |
Insertion Loss | Frequency (GHz) 1.03125 GHz |
SDD21(max) I5dB |
InfiniBand Specification Volume 2 Release 1.3 clause 6.8. 7.1 |
|
Differential Node Return Loss | Frequency (GHz) 0.05 ≤ f <5.6 5,6≤f |
SODD11 & SDD22(max) -12+1. 71*sqrt (f)) ·-67+131og10(f/7) |
InfiniBand Specification Volume 2 Release 1.3 clause 6.65 |
|
Insertion loss deviation | ILD≤0.75, ≤0.4286f-0.75, ≤2.25, ILD≥0.75, ≥0.75-0.4286f, ≥2.25 |
0.05 ≤ f < 3.50 3.50 ≤ f < 7.0 7≤ f < 10.5 0.05 ≤ f < 3.50 3.50 ≤ f < 7.0 7≤ f < 10.5 | f is frequency, in GHz InfiniBand Specification Volume 2 Release 1.3 clause 6.8. 7.1 |
|
Intra-Pair Skew | ≤100 ps(TDT Method) Rise time of 35 ps (20% ~ 80%) | (For reference) | ||
Inter-Pair Skew | ≤500 ps(TDT Method) Rise time of 35 ps (20% ~ 80%) | InfiniBand Specification Volume 2 | ||
Common mode Return Loss | ≤-2 dB @50MHz~14.1GHz | InfiniBand Specification Volume 2 | ||
Common mode to Differential Reflection (SDC11/SDC22) |
≤-16+2*f/3 @0.05~15GHz | InfiniBand Specification Volume 2 | ||
Environmental Characteristics |
Operating Temperature | -40~85°C | Cable operating temp. range | |
Thermal Shock | No evidence of physical damage | EIA-364-32 Test, condition I (10cycles) | ||
Cyclic Temp. & Humidity | No evidence of physical damage | EIA-364-31 Method III, Test Cond A | ||
Salt spray | 48 hours salt spraying after shell corrosive area less than 5% | EIA-364-26 | ||
Temperature Life | Performance meets the specification requirement | EIA-364-17, Method A, Test Cond 3 at 105°±2°C | ||
Mechanical Characteristics |
MechanicaI Vibration | Performance meets the specification requirement | EIA-364-28E.11 TCVII, Test Cond D 15minutes in X,Y,Z axis. | |
Cable Flex | Performance meets the specification requirement | EIA-444-1B | ||
Mechanical Shock | Performance meets the specification requirement | EIA-364-27B, TG-G. 3 times in 6 directions, 100g, 6ms | ||
Cable Plug Insertion | 40N Max. | Per QSFP MSA Rev 1.0 | ||
Cable plug Extraction | 30N Max. | Per QSFP MSA Rev 1.0. | ||
Latch retention force | 50N Min. No evidence of physical damage | EIA-364-13 | ||
Durability | 50 Time. No evidence of physical damage | EIA-364-09; perform plug&unplug cycles |
Specifications may change without notice. Display Product Photos Shown are samples for viewing, not actual products. Colours and styles may vary.