Economic solution for within rack, or rack-to-rack applications

General Details

Characteristics

  • Compatible with industry standard QSFP cages +Switches
  • EEPROM signature can be customized
  • FDR QSFP+cable assemblies are hot swappable
  • The programmed EEPROM signature enables the host to differentiate between a copper cable assembly and a fiber optic module
  • Low power consumption assists in making the passive copper cable assembly an economic solution for within rack, or rack-to-rack applications

Application

  • InfiniBand 4X SDR, DDR, QDR, FDR
  • Ethernet 10G,40G
  • FiberChannel 10G,40G, SAN, 4x16G
  • RapidIO, Myrinet 40G
  • Rack-to-Rack, Shelf-to-Shelf Interconnect
  • Networking, Storage
  • Hubs, switches, routers, servers

Fiberon’s FDR QSFP+ passive copper cables provide robust connections for leading edge 56 Gb/s systems. They are designed to be fully compatible in form factor and optical/electrical connections according to the QSFP Multi- Source Agreement.

QSFP+ (Quad SFP+) connectors provide four channels of data in one pluggable interface. Each channel is capable of transferring data at 14.2Gbps and supports a total of aggregate 56Gbps as specified for QSFP+. These interconnects have three times the density of SFP+ interconnects (MSA) and have been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.

Product Specs

FDR Copper QSFP+assemblies are offered in different wire gauges (AWG) depending on length.

Wire Gauge Cable Length
30AWG ≤ 1Meter
28AWG ≤ 2Meters
26AWG ≤ 3Meters
24AWG ≤4Meters

 

FDR QSFP+ 56Gb/s Copper Cable Overview

Test Type Test Item Target Reference
Electrical
Characteristics
Differential impedance 100+/-10ohm (Rise time of 100ps (20%- 80%)) InfiniBand Specification Volume 2
Insertion Loss Frequency (GHz)
1.03125 GHz
SDD21(max)
I5dB
InfiniBand Specification Volume 2
Release 1.3 clause 6.8. 7.1
Differential Node Return Loss Frequency (GHz)
0.05 ≤ f <5.6 5,6≤f
SODD11 & SDD22(max)
-12+1. 71*sqrt (f))
·-67+131og10(f/7)
InfiniBand Specification Volume 2
Release 1.3 clause 6.65
Insertion loss deviation ILD≤0.75,
≤0.4286f-0.75,
≤2.25,
ILD≥0.75,
≥0.75-0.4286f,
≥2.25
0.05 ≤ f < 3.50 3.50 ≤ f < 7.0 7≤ f < 10.5 0.05 ≤ f < 3.50 3.50 ≤ f < 7.0 7≤ f < 10.5 f is frequency, in GHz
InfiniBand Specification Volume 2
Release 1.3 clause 6.8. 7.1
Intra-Pair Skew ≤100 ps(TDT Method) Rise time of 35 ps (20% ~ 80%) (For reference)
Inter-Pair Skew ≤500 ps(TDT Method) Rise time of 35 ps (20% ~ 80%) InfiniBand Specification Volume 2
Common mode Return Loss ≤-2 dB @50MHz~14.1GHz InfiniBand Specification Volume 2
Common mode to Differential
Reflection (SDC11/SDC22)
≤-16+2*f/3 @0.05~15GHz InfiniBand Specification Volume 2
Environmental
Characteristics
Operating Temperature -40~85°C Cable operating temp. range
Thermal Shock No evidence of physical damage EIA-364-32 Test, condition I (10cycles)
Cyclic Temp. & Humidity No evidence of physical damage EIA-364-31 Method III, Test Cond A
Salt spray 48 hours salt spraying after shell corrosive area less than 5% EIA-364-26
Temperature Life Performance meets the specification requirement EIA-364-17, Method A, Test Cond 3 at 105°±2°C
Mechanical
Characteristics
MechanicaI Vibration Performance meets the specification requirement EIA-364-28E.11 TCVII, Test Cond D 15minutes in X,Y,Z axis.
Cable Flex Performance meets the specification requirement EIA-444-1B
Mechanical Shock Performance meets the specification requirement EIA-364-27B, TG-G. 3 times in 6 directions, 100g, 6ms
Cable Plug Insertion 40N Max. Per QSFP MSA Rev 1.0
Cable plug Extraction 30N Max. Per QSFP MSA Rev 1.0.
Latch retention force 50N Min. No evidence of physical damage EIA-364-13
Durability 50 Time. No evidence of physical damage EIA-364-09; perform plug&unplug cycles

Specifications may change without notice. Display Product Photos Shown are samples for viewing, not actual products. Colours and styles may vary.